Thursday, November 29, 2012

Engineers in a vacuum

It has become pretty clear to me that engineers are just way too isolated. They never get the feedback from reality which is necessary to actually learn to be a great engineer. Engineering school seems to be a lot more theory than hands on work but it just gets worse when they graduate. Engineers are asked to design things which they have never actually built relying only on their knowledge of abstract theories.

If I do a design, and it is wrong. I will never hear about it. A construction person will grumble a little bit when looking at the drawing, and just do it right. It is just easier than going through the trouble to fix the drawing. I thought that this was peculiar to utilities since they have dedicated people who do all construction and maintenance work. Because it is so dangerous engineers almost never get hands on experience. This  article in the Atlantic makes me think that this is a more general problem with engineering in America though. The factories are thousands of miles away, so the engineers never hear the grumbling.

But a problem soon became apparent. GE hadn’t made a water heater in the United States in decades. In all the recent years the company had been tucking water heaters into American garages and basements, it had lost track of how to actually make them.
The GeoSpring in particular, Nolan says, has “a lot of copper tubing in the top.” Assembly-line workers “have to route the tubes, and they have to braze them—weld them—to seal the joints. How that tubing is designed really affects how hard or easy it is to solder the joints. And how hard or easy it is to do the soldering affects the quality, of course. And the quality of those welds is literally the quality of the hot-water heater.” Although the GeoSpring had been conceived, designed, marketed, and managed from Louisville, it was made in China, and, Nolan says, “We really had zero communications into the assembly line there.”
To get ready to make the GeoSpring at Appliance Park, in January 2010 GE set up a space on the factory floor of Building 2 to design the new assembly line. No products had been manufactured in Building 2 since 1998. An old GE range assembly line still stood there; after a feud with union workers, that line had been shut down so abruptly that the GeoSpring team found finished oven doors still hanging from conveyors 30 feet overhead. The GeoSpring project had a more collegial tone. The “big room” had design engineers assigned to it, but also manufacturing engineers, line workers, staff from marketing and sales—no management-labor friction, just a group of people with different perspectives, tackling a crucial problem.
“We got the water heater into the room, and the first thing [the group] said to us was ‘This is just a mess,’ ” Nolan recalls. Not the product, but the design. “In terms of manufacturability, it was terrible.”
The GeoSpring suffered from an advanced-technology version of “IKEA Syndrome.” It was so hard to assemble that no one in the big room wanted to make it. Instead they redesigned it. The team eliminated 1 out of every 5 parts. It cut the cost of the materials by 25 percent. It eliminated the tangle of tubing that couldn’t be easily welded. By considering the workers who would have to put the water heater together—in fact, by having those workers right at the table, looking at the design as it was drawn—the team cut the work hours necessary to assemble the water heater from 10 hours in China to two hours in Louisville.
In the end, says Nolan, not one part was the same.
So a funny thing happened to the GeoSpring on the way from the cheap Chinese factory to the expensive Kentucky factory: The material cost went down. The labor required to make it went down. The quality went up. Even the energy efficiency went up.